Detail ABB 1SBL371001R8411 KONTAKTOR 3P 63A A63-30-11 110VAC

Perlengkapan Listrik Lainnya

Number of Main Contacts NO:
3

Number of Main Contacts NC:
0

Number of Auxiliary Contacts NO:
1

Number of Auxiliary Contacts NC:
1

Standards:
Devices complying with international standards IEC 947-1 / 947-4-1, and European standards EN 60 947-1 / 60 947-4-1. Electromagnetic compatibility (EMC) acc. to amendment A11 to IEC 947-1, EN 60 947-1 and amendment 2 to IEC 947-4-1

Rated Operational Voltage:
Auxiliary Circuit 690 V
Main Circuit 1000 V

Rated Frequency (f):
Auxiliary Circuit 50 / 60 Hz
Control Circuit 50 / 60 Hz

Conventional Free-air Thermal Current (Ith):
acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 125 A
acc. to IEC 60947-5-1, Θ = 40 °C 16 A

Rated Operational Current AC-1 (Ie):
(690 V) 40 °C 115 A
(690 V) 55 °C 95 A
(690 V) 70 °C 80 A

Rated Operational Current AC-3 (Ie):
(415 V) 55 °C 65 A
(440 V) 55 °C 65 A
(500 V) 55 °C 55 A
(690 V) 55 °C 43 A
(1000 V) 55 °C 25 A
(380 / 400 V) 55 °C 65 A
(220 / 230 / 240 V) 55 °C 65

Rated Operational Power AC-3 (Pe):
(415 V) 37 kW
(440 V) 37 kW
(500 V) 37 kW
(690 V) 37 kW
(1000 V) 33 kW
(380 / 400 V) 30 kW
(220 / 230 / 240 V) 18.5 kW

Rated Operational Power AC-6b (Pe):
(230 / 240 V) 40 °C, 50 / 60 Hz 25 kvar
(230 / 240 V) 55 °C, 50 / 60 Hz 25 kvar
(230 / 240 V) 70 °C, 50 / 60 Hz 23 kvar
(400 / 415 V) 40 °C, 50 / 60 Hz 43 kvar
(400 / 415 V) 70 °C, 50 / 60 Hz 39 kvar
(400 / 415 V) 55 °C, 50 / 60 Hz 43 kvar
(440 V) 40 °C, 50 / 60 Hz 47 kvar
(440 V) 55 °C, 50 / 60 Hz 47 kvar
(440 V) 70 °C, 50 / 60 Hz 42.5 kvar
(500 / 550 V), 40 °C, 50 / 60 Hz 54 kvar
(500 / 550 V) 55 °C, 50 / 60 Hz 54 kvar
(500 / 550 V) 70 °C, 50 / 60 Hz 48.5 kvar
(690 V) 40 °C, 50 / 60 Hz 74 kvar
(690 V) 55 °C, 50 / 60 Hz 74 kvar
(690 V) 70 °C, 50 / 60 Hz 67 kvar

Rated Breaking Capacity AC-3:
8 x Ie AC-3

Rated Making Capacity AC-3:
10 x Ie AC-3

Rated Operational Current AC-15 (Ie):
(500 V) 2 A
(690 V) 2 A
(24 / 127 V) 6 A
(220 / 240 V) 4 A
(380 / 400 V) 3 A

Short-Circuit Protective Devices:
Auxiliary Circuit - gG Type Fuses 10 A
gG Type Fuses 125 A

Rated Short-time Withstand Current Low Voltage (Icw):
at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 650 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 135 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 250 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 1000 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 370 A
for 0.1 s 140 A
for 1 s 100 A

Maximum Breaking Capacity:
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 1300 A
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 630 A

Maximum Electrical Switching Frequency:
(AC-1) 600 cycles per hour
(AC-2 / AC-4) 150 cycles per hour
(AC-3) 600 cycles per hour

Rated Operational Current DC-13 (Ie):
(24 V) 6 / 144 A
(48 V) 2.8 / 134 A
(72 V) 1 / 72 A
(125 V) 0.55 / 69 A
(250 V) 0.3 / 75 W

Rated Insulation Voltage (Ui):
acc. to IEC 60947-4-1 1000 V
acc. to IEC 60947-5-1 690 V
acc. to UL/CSA 600 V

Rated Impulse Withstand Voltage (Uimp):
8 kV

Mechanical Durability:
10 million

Maximum Mechanical Switching Frequency:
3600 cycles per hour

Rated Control Circuit Voltage (Uc):
50 Hz 110 V
60 Hz 110 ... 120 V

Coil Consumption:
Average Holding Value 50 / 60 Hz 18 V·A
Average Pull-in Value 50 Hz 190 V·A
Average Pull-in Value 60 Hz 180 V·A

Operate Time:
Between Coil De-energization and NC Contact Closing 7 ... 14 ms
Between Coil De-energization and NO Contact Opening 4 ... 11 ms
Between Coil Energization and NC Contact Opening 7 ... 22 ms
Between Coil Energization and NO Contact Closing 8 ... 27 ms

Mounting on DIN Rail:
TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
TH75-25 (75 x 25 mm Mounting Rail) acc. to IEC 60715

Mounting by Screws (not supplied):
2 x M6 screws placed diagonally

Connecting Capacity Main Circuit:
Flexible with Cable End 6 ... 16 mm²
Rigid Cable 6 ... 25 mm²

Connecting Capacity Auxiliary Circuit:
Flexible with Cable End 0.75 ... 2.5 mm²
Rigid Cable 1 ... 4 mm²

Degree of Protection:
acc. to IEC 60529, IEC 60947-1, EN 60529 Auxiliary Terminals IP20
acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20
acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP10

Connecting Terminals (delivered in open position) Main Poles:
M 6 (+,-) pozidriv 2 screws with 1x (13 x 10 mm) connector

Terminal Type:
Screw Terminals